ADL400 Three Phase Din Rail Energy Meter
General
Three phase din rail energy meter ADL400 can measure all power parameters, with 2~31 sub-harmonic and total harmonic content detection. With RS485 communication interface and optional MODBUS-RTU protocol, the power meter can be widely used in various control systems, SCADA systems, and energy management systems.
Main Functions
Panel Overview
Main Parameters
Main Features
|
Diverse Electric Parameters Measurement ● kWh (3-phase positive Kilowatt-hours) ● kVarh (Kilovar-hours) ● Harmonic (2~31st voltage¤t)---Standard ● U (3-phase Voltage) ● I (3-phase Current) ● P (Power) ● Q (Reactive power) ● F (Frequency) ● S (Apparent power) ● PF (Power factor) |
|
|
Multi-rate/Flexible Tariff ● 4 Time zone ● 4 Tariff rate (Spike, Peak, Flat, Valley) ● 2 Time period list ● 14 Time period by day ● Data Frozen (last 48 months or last 90 days) ● Max demand and occurrence time |
|
|
HMI for Common Configuration ● PT or CT ratio ● Wiring methods (3P4W or 3P3W) ● Back linght time ● RS485 (MODBUS-RTU) communication setting |
|
Wiring
Direct Connect Type

PIN/Terminal Overview of ADL400 (Direct Connect Type)

Power Wiring: 3-phase 4-wire via direct connect

Power Wiring: 3-phase 3-wire via direct connect

RS485 Wired Communication of ADL400 (Direct Connect Type) with IoT Gateway CT Operated Type

PIN/Terminal Overview of ADL400 (CT Operated Type)

Power Wiring: 3-phase 4-wire CT operated
DIN Rail Installation
Application in IoT System
Dimensions

Package
|
Packaging Overview
(Minimum)
|
|
|
|
Packing Dimension and Weight
(Minimum)
|
Minimum Package Contain 1 pcs Products
Dimension: 170mm*150mm*130mm |
Total G.W. (1 pcs) 0.66 KG |
|
Packing Dimension and Weight
(Large) |
Large Package Contain 36 pcs Products Dimension: 540mm*480mm*280mm |
Total G.W. (36 pcs)
10.09 KG |
|
Average Lead Time |
Manufacturing: 3~4 days (If paired with system need extra 1~2 days for adjustment)
|
Shippment: 8~9 days
(World Wide Shipment)
|
|
Product
HS Code |
9028301400 |
|
|
Country of Origin |
China |
|
Technical Datasheet
|
Specification |
3 phase 3 wires, 3 phase 4 wires |
||
|
Measurement |
Voltage |
Reference voltage |
3×100V、 3×380V、3×57.7/100V、 3×220/380V |
|
Consumption |
<10VA(Single phase) |
||
|
Impedance |
>2MΩ |
||
|
Accuracy class |
Error±0.2% |
||
|
Current |
Input current |
3×1(6)A, 3×10(80)A |
|
|
Consumption |
<1VA Single phase rated current |
||
|
Accuracy class |
Error±0.2% |
||
|
Power |
Active, reactive, apparent power, error±0.5℅ |
||
|
Frequency |
45~65Hz,Error±0.2% |
||
|
Meter |
Energy |
Active energy(Accuracy class: 0.5) reactive energy(Accuracy class 2) |
|
|
Clock |
≤0.5s/d |
||
|
Digit signal |
Energy pulse output |
1 active photocoupler output |
|
|
pulse |
Width of pulse |
80±20ms |
|
|
Pulse constant |
400imp/kWh,10000imp/kWh(Correspond with the basic current) |
||
|
communication |
Interface and communication protocol |
RS485:Modbus RTU |
|
|
Range of communication address |
Modbus RTU:1~ 247; |
||
|
Baud rate |
1200bps~19200bps |
||
|
environment |
working temperature |
-25℃~+55℃ |
|
|
Relative humidity |
≤95℅(No condensation) |
||