ADW210 Multi-circuit IoT Smart Energy Meter

  • Monitoring Up to 4 circuits 3-phase or 12 circuits 1-phase.
  • Measurement kWh, kVarh, Current, Voltage, Power, 2~31st Harmonic and etc
  • Voltage Rating 3x380V~456Vac L-L & 3x220~264Vac L-N
  • Current Rating 5A, 100A, 400A or 600A AC (with external CTs)
  • Frequency 45~65Hz
  • Communication RS485 (MODBUS-RTU)
  • Extra Function Wireless Communication (4G, WiFi, LoRa and etc); Cable Temperature Measurement; DO/DI Function
  • Display LCD
  • Dimension 87.8*72*97.7mm(L*W*H) --- Main Body
  • Wiring 3-phase 4-wire & 3-phase 3-wire Connection
  • Installation 35mm DIN Rail
  • Certificate CE; LVD

Products Overview

图片13

Multi-circuits Monitoring

● Monitor up to 4 circuits 3-phase or 12 circuits 1-phase

● Paired CTs with specs of 5A/1.25mA; 100A/20mA; 400A/100mA or 

600A/100mA

● External CTs Connectwith ADW210 Main Body thrrough RJ12 Interface

 

 图片14

Expanded Communication Module --- AWT100

● 4G (Global general module)

● WiFi

● LoRaWAN

● LoRa 

● NB-IoT

 图片15

Cable Temperature&Residual Current Measurement Module --- MTL

● Temperature Measurement:-20℃~+100℃

● Residual Current Measurement:10~3000 mA

● Accuracy:Temperature:± 2℃; Residual Current:1% (Class 1)

 图片16

DO/DI Switch Extra Function Module --- MK

● 12 channel DI (Digital Input)

● 4 channel DO (Digital Output)

 图片17

Wiring

图片18

ADW210 3-phase 4-wire Power Wiring

图片19

ADW210 3-phase 3-wire Power Wiring Diagram

图片20

Installation Instruction

Common Applicaiton

 图片21

 

图片22

 

图片23
 图片24

 

Typical Networking Connection

图片25

Technical Parameters (Prototype/Main body)

Parameters

Description

Input

 

 

Voltage

AC 3×220V/380V

Overload: 1.2 times of rated value (continuous); 2 times of rated
value / 1s

Power consumption:≤ 0.5VA

 

 

Current

AC 5A、100A、400A、600A;(external open-type CT)

Overload: 1.2 times of rated value (continuous); 10 times
of rated value / 1s

Power consumption:≤ 0.5VA

Frequency

45~65Hz

Measuring

Accuracy

Voltage&Current

Class 0.5

Active Power

Class 1

Reactive Power

Class 2

Frequency

0.05Hz

2~31st harmonic

± 1%

Auxiliary Power

AC/DC 85~265V;consumption≤10VA;

EMC

Better than grade 3

Safety

Withstand Voltage

>AC 2000V/1min

Insulation Resistance

>100MΩ

Environment

Working Temperature

-20℃~+60℃

Storage Temperature

-40℃~+70℃

Humidity

≤95% (No condensation)

Altitude

≤2500m

Technical Parameters (paired Current Transformer)

Paired CT

Primary Current

Secondary Current

Aperture(Hole size)

Accuracy Class

AKH-0.66/K-φ10N

5A

1.25mA

10mm

Class 0.5

AKH-0.66/K-φ16N

100A

20mA

16mm

Class 0.5

AKH-0.66/K-φ24N

400A

100mA

24mm

Class 0.5

AKH-0.66/K-φ36N

600A

100mA

36mm

Class 0.5

AKH-0.66-L-45 

(for residual current)

/

/

/

Class 1

Download_file
ADW210 MANUAL