BM200-DI Signal Isolated Safety Barrier

  • Measurement Alternating Current (AC)
  • Installtion Clamp-on easy installation
  • Primary Current Input Max 10000A AC
  • Secondary Current Output 200mV/333mV
  • Perforation Size 90/150/200/300 mm

General

BM200 isolated safety barrier can transmit signals between the safe area and the dangerous area, and limit the energy transfer from the safe area to the dangerous area caused by the fault. The voltage, current, temperature, resistance signals generated by the equipment (transmitter) on the dangerous side are isolated and converted into corresponding linear voltage and current signals outputting to the safe area. The product requires independent power supply, and the input/output/power supply is isolated. It can be used in current source, two-wire, three-wire transmitter equipment.

图片1

Features

图片2

Dimension

图片3

Wiring

图片4图片5图片5

Structure

图片7

Photos on Site

图片8

Packaging

MINIMUM PACKAGE

图片9 图片10 图片11 图片12

MINIMUM PACKAGE

Package dimensions(1 PC)

17*15.5*12.5cm

Package Weight(1 PC)

0.25Kg

WHOLE BOX PACKAGE

Package dimensions(10 PCS)

45.5*26*19.5

Package Weight(10 PCS)

3kG

PRODUCT HS CODE

9030339000

Technical Datasheet

Channel type

Single-way input and single-way output, single-way input and double-way output,

double-way input and double-way output

Input type

Current/Voltage/Thermal resistance Pt100/Resistance/Thermocouple

Input signal

0~20mA /4~20mA

0~5V /0~10V /1~5V (Distribution voltage: 12V/20mA) PT100 /0~10K/K、E、T、J、N、R、S、B

Output signal

0~20mA /4~20mA (Safe side input); Load resistance: ≤550Ω 0~5V /1~5V (Safe side input); Load resistance: ≥330K

0~10V (Safe side input); Load resistance: ≥500K

Transmission accuracy

0.2%

Temperature modulus

50ppm/℃ (The output signal is current)

Response time

5ms to reach 90% of final value

(RTD Pt100/resistance/thermocouple input: 1s to reach 90% of final value)

Power supply

20~35V DC

Work temperature

-20℃~+60℃

Fix mode

Rail installation

Dielectric strength

Intrinsically Safe and Non-Intrinsically Safe ≥2500V AC; Power supply and Non-Intrinsically Safe ≥500V AC

Note:Intrinsically Safe is input, Non-Intrinsically is output