Leave Your Message
Products Categories
Featured Products

DJSF1352-RN-2 DC Din rail Energy meter

  • Measurement kWh, kVarh, Power, Current, Voltage and etc
  • Current Rating 75mV,0-5V,0-200mA
  • Voltage Rating DC 0-1000V, DC0-100V
  • Application DC Battery; Charging Pile; Solar PV and etc
  • Communication RS485 (MODBUS-RTU)
  • Display LCD Display
  • Dimension 36*70*90 mm
  • Installation 35mm DIN Rail
  • Power Supply 85~265V AC/DC; 12V-48V(±10%) DC

General

DJSF1352-RN-2 rail-mounted DC energy meter is designed mainly for DC charging piles, telecommunication base stations, solar photovoltaic and other application occasions. This series of instruments can measure voltage, current, power and positive and negative energy in the DC system. The test results can be used for local display and can also be connected with industrial control equipment and computers to form a measurement and control system.

Features

●Accuracy

Class 0.5


●Pulse output

One channel power pulse output, 1-9999imp/kWH


●Communication

RS 485 Modbus-RTU,DL/T 645-2007,DLT698


 1

●Power Supply:

AC/DC 85-265V or DC12V-48V


●Dimension(L*W*H):

36*70*90 mm


●Temperature:

Normal operating temperature:-25℃~+65℃

Storage temperature:-40℃~+80℃

 2

Display Sample

6

Wiring

5

Terminals and wiring
8_17_1

                                                                                                   Shunt input
9_14_1

                   0-5V output                                                                                 0-20mA output

Hall Sensor input

Technical parameters Indicators
Input Nominal value Voltage input range Current input
DC 0-1000V, DC0-100V Shunt:0-75mV;
   
See the physical wiring diagram Hall sensor:0-20mA、4-20mA、0-5V,0-10V、0-200mA
Overload 1.2 times rated (continuous); 2 times rated/1 second;
Power consumption Voltage: ≤0.2VA, current ≤0.1VA
Accuracy class Class 0.5
Function Display 8-bit segment LCD screen (LCD)
Communication Interface RS485, infrared
Communication protocol Modbus-RTU,DL/T 645-2007, DLT698
Pulse output One channel power pulse output
See the SYS->PLUS display in the meter menu setting
 
For example: The meter displays 100, which is 100imp/kWH
Power Supply Voltage range AC/DC 85-265V or DC12V-48V(Auxiliary power supply code P1)
Power consumption ≤ 6W
Power frequency withstand voltage

Power supply//signal input//RS485 communication 4kV/1min;

Except for power supply, signal input and RS485 communication, other unconnected circuits 2kV/1min

Insulation resistance ≥ 40M Ω
Average barrier-free working hours ≥50000h
Environment Temperature Normal operating temperature: -25 °C ~ +65 °C;
 
Limit working temperature: -40 °C ~ +70 °C;
 
Storage temperature: -40℃~+80℃
Humidity ≤93%RH, no condensation, no corrosive gas
Altitude ≤2500m
Download_file
DJSF1352-RN-2 MANUAL