Leave Your Message
Products Categories
Featured Products

DJSF1352-RN-6 Din Rail DC Energy Meter

  • Power Supply AC/DC 85-265V or DC12V-48V
  • Accuracy Class 0.5
  • Pulse output Two-way power pulse output
  • Communication protocol Modbus-RTU,DL/T 645-2007,DLT698
  • Rated U Voltage: DC 0-1500V, DC0-100V Shunt:0-75mV
  • Rated I Hall sensor:0-5V,0-200mA
  • Display 8-bit segment LCD screen (LCD)
  • Communication Interface RS485(two options)
  • Working temperature -25℃~+65℃
  • Altitude ≤3000m

General

DJSF1352-RN-6 rail-mounted DC energy meter is designed mainly for DC charging piles, telecommunication base stations, solar photovoltaic and other application occasions. This series of instruments can measure voltage, current, power and positive and negative energy in the DC system. The test results can be used for local display and can also be connected with industrial control equipment and computers to form a measurement and control system.

Products Overview

DJSF1352-RN-6-2

Features

Accuracy
Class 0.5

Pulse output
2 channel power pulse output, 1-9999imp/kWH

Communication
RS 485 Modbus-RTU,DL/T 645-2007,DLT698

DJSF1352-RN-6-1
Power Supply:
AC/DC 85-265V or DC12V-48V
Dimension(L*W*H):
108*70*94 mm
Temperature:
Normal operating temperature:-25℃~+65℃
Storage temperature:-40℃~

DJSF1352-RN-6-3

Dimension & Installation

photobank

Shape and installation dimensions

photobank (1)

Terminals and wiring

photobank

Shunt input and Hall sensor input

Technical Datasheet

Technical Parameters

Index

Input

 

Nominal value

Voltage input range

Current input

DC 0-100V、DC 0-1500V

See the physical wiring diagram

Shunt: 0-75mV

Hall sensor: 0-5V, 0-200mA

 

Overload

1.2 times can sustain normal operation, 2 times can sustain 1 second

Power consumption

Voltage: ≤0.2VA, current ≤0.1VA

Accuracy class

Class 0.5

Function

Display

8-bit segment LCD screen (LCD)

Communication Interface

RS485(two options)

Communication protocol

 

Modbus-RTU,DL/T 645-2007,DLT698

 

 

Switch

Switch output (DO)

2 relay outputs, 2A/30VDC or 2A/250VAC

Switch input (DI)

2 dry contact inputs

Analog

Analog output (AO)

4-20mA output (0.5 level)

Pulse output

Two-way power pulse output (the second power pulse can be switched to second pulse)

See the display in SYS->PULS in the meter menu setting, for example: display 100, which means 100imp/ kWH

Working power supply

Voltage

AC/DC 85-265V or DC 12V-48V

Power consumption

≤ 10W

Power frequency

withstand voltage

Power supply//signal input//RS485 communication 4kV/1min;

Except for power supply, signal input and RS485 communication, other unconnected circuits are 2kV/1min

Insulation resistance

 

≥ 100M Ω

Average barrier-free working time

≥50000h

Environment

Temperature

Working temperature: -25℃~+65℃

Storage temperature: -40℃~+80℃

Humidity

≤95%RH, no condensation, no corrosive gas

Altitude

≤3000m

Download_file
DJSF1352-RN-6 DC Energy Meter Manual