DTSD1352-C Solar Inverter Smart Meter

  • Measurement 3-phase kWh (0.5S), Active Power, Reactive Power, Current, Voltage, Harmonic and etc
  • Voltage Rating 3x220/380V, 3x57.7/100V (3P4W); 3x380V, 3x100V (3P3W)
  • Current Rating 3x10(80)A; 3x1(6)A
  • Frequency 45~65Hz
  • Commnunication RS485 (MODBUS-RTU) and Infrared
  • Multi-rate Spike, Peak, Valley and Flat kWh
  • Extra Function Cable Temperature Measurement and DO/DI
  • Display LCD (8 digits)
  • Dimension 127*88*70mm (L*W*H)
  • Wiring 3-phase 4wire; 3-phase 3-wire
  • Installation 35mm DIN Rail
  • Certificate IEC; CE

Products Overview

1

Main Features


Diverse Electricity Parameters Measurement

● Harmonic (2~31st voltage&current)---Optional

● F (Frequency)

● U (3-phase Voltage)

● I (3-phase Current)

● kWh (3-phase positive Kilowatt-hours)

● kVarh (Kilovar-hours)

● P (Power)

● Q (Reactive power)

● S (Apparent power)

● PF (Power factor)

 2

Multi-rate/Flexible Tariff
● 4 Time zone
● 4 Tariff rate (Spike, Peak, Flat, Valley)
● 2 Time period list
● 14 Time period by day
● Data Frozen (last 48 months or last 90 days)
● Max demand and occurrence time
 3

Wiring

4
4

Application

6

Package

Technical Datasheet

1.Function description

Function

Function description

Function provide

 

Measurement of kWh

Active kWh (positive and negative)

■

Reactive kWh (positive and negative)

■

A, B, C phase positive active kWh

■

Measurement of electrical parameters

U、I、P、Q、S、PF、F

■

■

Measurement of

2~31ST Voltage and current harmonic

□Note 1

LCD Display

8 bits section LCD display, background light

■

Key programming

4 keys to communication and set parameters

■

Pulse output

Active pulse output

■

Reactive pulse output

□Note 2

Clock pulse output

□Note 2

Multi-tariff and functions

Active switch input

□Note 3

Switch output

□Note 2

Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates

□

Max demanded kWh and time happened

□

Frozen data on last 48 months, last 90days

□

Date, time

□

Communication

Infrared communication

■

The first communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU 

□

The second communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU 

□Note 3

Temperature measurement

Support 3 outlay NTC temperature

□Note 4

“■” means standard, “□” means optional.

 

2.Technical parameter

Specification

3 phase 3 wires, 3 phase 4 wires

Voltage

Reference voltage

3×100V、 3×380V、3×57.7/100V、 3×220/380V

Consumption

<10VA(Single phase)

Impedance

>2MΩ

Accuracy class

 Error±0.2%

Current

Input current

3×1(6)A (second connection with 3- phase load line via extra selected CTs)

3×10(80)A (direct connection with 3-phase load line via CTs built in ADL3000-E)

Consumption

<1VA(Single phase rated current)

Accuracy class

 Error±0.2%

 Power

Active, reactive, apparent power, error±0.5℅

 Frequency

45~65Hz, Error±0.2%

Temperature

-40℃~99℃

 Energy

Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2)

 Clock

≤0.5s/d

Energy pulse output

1 active optocoupler output, 1 reactive optocoupler output

Switching output

1 Switching output

Switching input

1 optocoupler input

Width of pulse

80±20ms

Pulse constant

6400imp/kWh,400imp/kWh(Correspond with the basic current)

Interface and communication

RS485:Modbus RTU

Range of communication address

Modbus RTU:1~ 247;

 Baud rate

1200bps~19200bps

Relative temperature

-25℃~+55℃

Relative humidity

≤95℅(No condensation)

 