PZ72L-DE DC Multi-function Energy Meter
Main Functions
Panel Overview
Main Parameters
Outline Dimension
Cut-out Dimension
About Packagement
|
Packaging Overview (Minimum) |
|
|
|
Packing Dimension and Weight (Minimum) |
Minimum Package Contain 1 pcs Products Dimension: 230mm*145mm*120mm
|
Total N.W. (1 pcs) 0.71 KG |
|
Packing Dimension and Weight (Large) |
Large Package Contain 48 pcs Products Dimension: 615mm*480mm*395mm
|
Total N.W. (48 pcs) 16.09 KG |
|
Average Lead Time |
Manufacturing: 3~4 days (If paired with system need extra 1~2 days for adjustment)
|
Shippment: 8~9 days (World Wide Shipment) |
|
Product HS Code |
9028309000
|
|
|
CO Country of Origin |
China
|
|
Wiring Illustration

DC Voltage Signal (1000V DC) Input via direct Connection & DC Current Signal (75mV DC) input via -/75mV Shunts

DC Voltage Signal (1000V DC) Input via direct Connection & DC Current Signal (0~20mA or 4~20mA DC) input via Hall Sensors
Installation Instruction
|
1. Cut out a hole on the object on where we will intall the meter according to dimension of meter referred above.
2. Remove the buckle on the meter off. |
|
3. Install the meter into the cut-out hole.
4. Buckle up and fixed the meter. |
Function Overview
|
Function |
Description&Value |
|
Measurement |
1-circuits DC Voltage, Current, Power, kWh |
|
Display |
LCD display |
|
Communication (Optional) |
RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity) Baud Rate 1200~38400 bps etc. |
|
DI/DO Switching (Optional) |
DI (Digital input): 2-channel digital input,dry contact, built-in power supply DO (Digital output): 2-channel digital output (relay output) with NO Contact, Capacity: 2A/30V DC or 2A/250V AC |
|
±12V Power Output (Optional) |
Serve as the power supply for 1 Hall Sensors with ±12V DC |
|
Multi-rate/tariff (Optional) |
2 Time Schedules; 4 Time Zone for a year; 12 time periods by days set for 1 time schedule; 4 Tariff Rates (Spike, Peak, Flat, Valley); Min. Time Interval=15 min. |
Main Parameters
|
Parameter |
Description&Value |
|
|
Input |
Rated Voltage |
DC Voltage Input: 0~1000V DC (via direct connetion); Input Resistance: ≥ 6kΩ/V |
|
Rated Current |
DC Current Input: 10A DC (via direct Connection); 0~20mA or 4~20mA (via Hall Sensors); 75mV (via Shunts) |
|
|
Overload |
Current&Voltage input overload:1.2 times rated value(continuous); 10 times rated value /1 second |
|
|
Power Consumption |
Power consumption of each current input circuit is less than 1mW |
|
|
Measuring Accuracy |
Class |
0.5% |
|
Power Supply |
Voltage Range |
85-265V AC/DC; 20~60V DC (±20%) |
|
Power Consumption |
≤ 2W |
|
|
Pulse Constant |
Voltage and current specifications:750V、300A,Default pulse constant:100imp/kWh |
|
|
Voltage and current specifications:1000V、300A,Default pulse constant:100imp/kWh |
||
|
Insulation resistance |
≥ 100MΩ |
|
|
Power frequency withstand voltage |
Between Power supply//Switching Output// Current Input//voltage Input and Transmitting// Communication //Pulse Output//switching input AC 2 kV 1min; Between Power supply、switching output、Current Input、voltage Input AC 2 kV 1min; Between Transmitting、Communication、Pulse Output、switching input AC 1kV 1 min; |
|
Environment
|
Condition |
Description&Value |
|
Temperature |
Operation: -25℃~+65℃; Storage: -40°C ~+80°C |
|
Humidity |
≤95%RH,no condensation,without corrosive gas |
|
Altitude |
≤ 2500m |